LoviX®
Straight Joints
Transition Joint for extreme conditions
Reliable cable jointing when standard solutions fail.
Designed for high mechanical stress and demanding environments.
Ideal for:
- High mechanical stress areas Offshore / industrial environments
- Long-term reliability requirements
- Complex cable transitions
Standard joints are not always designed for extreme conditions.
This can lead to:
– Premature failure
– Costly downtime
– Safety risks
LoviX® R is the new standard for strong, watertight and durable cable joints in medium-voltage grids. The electrical insulation made of silicone rubber and a robust outer shell filled with Protolin® resin ensure a robust cable connection. These cable joints guarantee long-term reliability.
The XR Transition Joint is engineered for demanding applications where reliability is critical.
Key benefits:
✔ High mechanical strength
✔ Durable insulation system
✔ Proven long-term performance
✔ Compatible with multiple cable types
Applications
Medium-voltage grids are more heavily burdened by electrification, grid reinforcement and sustainable feed-in. This requires a cable joint that is not only reliable now, but also prepared for future requirements. LoviX® R offers just that: a strong, waterproof and durable cable connection that prevents failures, extends the life of networks and reduces overall costs. Premium performance for critical MS energy grids — exactly where Lovink makes the difference.
- Type-tested according to international standards
- Applied in critical infrastructure projects [case]
- Developed with decades of cable jointing expertise
Product Specifications
Key Characteristics of the Series:
Voltage 12 – 36kV
Cable Types XLPE/EPR
Conductor Range up to 630mm2
Suitable for 1-core
Select the connecting joint you would like more information about in the table below
* The indicated conductor cross-section is indicative, the diameter over insulation and sheath is decisive.
| Application area | Type | Cable | Conductor cross-section (mm²)* | Insulation diameter | Max. outer sheath diameter (mm) |
|---|---|---|---|---|---|
| 12 kV | R70 | Polymeric XLPE/EPR/HPTE | 800-1000 | 35 - 54 | 40 - 70 |
| Polymeric XLPE/EPR/HPTE | 630 | 35 - 54 | 40 - 70 | ||
| R50 | Polymeric XLPE/EPR/HPTE | 95 - 240 | 19 - 32 | 24 - 50 | |
| R60 | Polymeric XLPE/EPR/HPTE | 185 - 400 | 30 - 42 | 60 | |
| Polymeric XLPE/EPR/HPTE | 400 - 630 | 30 - 42 | 60 | ||
| 24 kV | R50 | Polymeric XLPE/EPR/HPTE | 95 - 240 | 19 - 32 | 24 - 50 |
| R60 | Polymeric XLPE/EPR/HPTE | 185 - 400 | 30 - 42 | 60 | |
| Polymeric XLPE/EPR/HPTE | 400 - 630 | 30 - 42 | 60 | ||
| R70 | Polymeric XLPE/EPR/HPTE | 630 - 1000 | 35 - 54 | 40 - 70 | |
| Polymeric XLPE/EPR/HPTE | 400-630 | 35-54 | 40-70 | ||
| 36 kV | R70 | Polymeric XLPE/EPR/HPTE | 630 - 1000 | 35 - 54 | 40 - 70 |
| Polymeric XLPE/EPR/HPTE | 400 - 630 | 35 - 54 | 40 - 70 |
Already selected the right Joint for your project?
We will be happy to provide you with a quoation.