LoviSil®
End Joints
Ensure safe and reliable cable termination in every situation
Protect cable ends and maintain network reliability during project completion or decommissioning
Problem
At the end of a cable route or during decommissioning, cables must be safely terminated
Without proper protection, cable ends are exposed to moisture, dirt and mechanical stress, increasing the risk of failure
Solution
LoviSil end joints provide a fully sealed and insulated termination
This ensures long-term protection and reliable performance, even in demanding underground environments
The LoviSil® end joint ensures a safe, reliable termination of medium-voltage cables – essential at the end of a route or when (partially) decommissioning a cable route. Thanks to the well thought-out construction of the cable joint, the insulation and mechanical protection remain intact. This keeps your network robust, even under demanding conditions.
Applications
The LoviSil® end joint is particularly suitable for utilities, industrial networks and infrastructure projects where cable routes end or where parts of the grid are decommissioned. Whether you are renovating, finishing a route or need a flexible delivery — this cable joint offers a safe, sustainable and future-proof solution for any medium-voltage grid.
| Application area | Type | Cable | Conductor cross-section (mm²)* | Crossed conductor cross-section (mm²) | Max. outer sheath diameter (mm) |
|---|---|---|---|---|---|
| 12 kV | M75 | Polymeric / PILC (1-core) | 95 - 630 | N/A | 72 |
| Polymeric / PILC (3 x 1-core) | 35 - 150 | N/A | 33 | ||
| Polymeric / PILC (3-core) | 35 - 150 | 35 - 120 | 72 | ||
| M85 | Polymeric / PILC (1-core) | 800 - 1000 | N/A | 82 | |
| Polymeric / PILC (3 x 1-core) | 95 - 240 | N/A | 38 | ||
| Polymeric / PILC (3-core) | 95 - 240 | 95 - 185 | 82 | ||
| M105 | Polymeric / PILC (1-core) | 800 - 1000 | N/A | 105 | |
| Polymeric / PILC (3 x 1-core) | 95 - 400 | N/A | 48 | ||
| Polymeric / PILC (3-core) | 95 - 400 | 300 | 105 | ||
| 24 kV | M75 | Polymeric / PILC (1-core) | 95 - 240 | N/A | 72 |
| M85 | Polymeric / PILC (1-core) | 300 - 630 | N/A | 82 | |
| Polymeric / PILC (3 x 1-core) | 95 - 150 | N/A | 38 | ||
| Polymeric / PILC (3-core) | 95 - 150 | 95 - 150 | 82 | ||
| M105 | Polymeric / PILC (1-core) | 300 - 630 | N/A | 82 | |
| Polymeric / PILC (3 x 1-core) | 95 - 400 | N/A | 48 | ||
| Polymeric / PILC (3-core) | 95 - 400 | 240 | 105 | ||
| 36 kV | M85 | Polymeric / PILC (1-core) | 70 - 500 | N/A | 82 |
| M105 | Polymeric / PILC (1-core) | 630 - 1000 | N/A | 105 |
Already selected the right Joint for your project?
We will be happy to provide you with a quoation.